Corgi Direct Gid1 Essential Gas Safety - Domestic 10th Edition Kit (volumes 1 & 2)

Part Code
COR.C004980
Man part no.
GID1
Loading your price…
Checking stock…

Product Description

Manufacturers Part Number: GID1

GID1 Safety Manual Kit



Introducing CORGI Directs best-selling gas installer manual kit for domestic gas installers, these comprehensive and authoritative manuals are packed full of technical information covering the essential gas safety elements of any domestic gas installation. The manuals continue to be an essential on the job technical reference source for the professional gas engineer.



The manual draws upon various British Standards, Institution of Gas Engineers and Manager and Liquid Gas UK Standards, Codes Practice, as well as Legislation to be THE reference source for the modern domestic gas operative / business.



To ensure that you are as up to date as possible, the GID1 10th Edition Kit (Volumes 1 & 2) now includes our NEW 5th Edition Tightness Testing and Purging Pocket Guide (TTP1) that comprehensively covers the requirements of the recently published IGEM/UP/1B Edition 4 that comes fully into force on 1st October 2026.




Summary of Standards & Regulatory Updates Included in This Kit



IGEM/UP/1B Edition 4: Tightness Testing and Direct Purging of Small Liquefied Petroleum Gas / Air, Natural Gas and Liquefied Petroleum Gas Installations


Natural Gas Procedures are fully integrated into the included 5th Edition TTP1 Pocket Guide, covering updated tightness testing and direct purging procedures.


BS 5440-1: 2023: Chimneys & Flues


BS 5440-2: 2023: Appliance Ventilation


IGEM/UP/17 Edition 2: Shared Chimney & Flue Systems for Domestic Gas Appliances




Kit Contents



1 x GID1 Volume 1 (10th Edition)


1 x GID1 Volume 2 (10th Edition)


1 x NEW TTP1 Pocket Guide: Tightness Testing & Purging (5th Edition: IGEM/UP/1B Edition 4)


1 x Premium Carry Case




Overall Contents Covered Across the Kits



Gas safety legislation


Gas emergency actions and procedures


Characteristics of combustion


Appliance ventilation


Installation pipework and fittings


Tightness testing and direct purging (natural gas)


Checking and setting regulators, burner pressures and gas rates


Gas Industry Unsafe Situations Procedure


Emergency controls and isolation valves


Industry notices, warning labels and forms


Gas safety devices and controls


Chimney standards, testing and commissioning


Domestic gas meters and re-establishing gas supplies / re-lighting appliances


Landlord Gas Safety Records (CP12)


General LPG safety information and requirements


Overview Breakdown by Volume




Inside the GID1 Volume 1



Gas safety legislation


Gas emergency actions and procedures


Characteristics of combustion


Ventilation


Installation of pipework and fittings


Checking and / or setting regulators


Gas Industry Unsafe Situations Procedure


Emergency controls and isolation valves


Emergency notices, warning labels and forms


Checking / setting burner pressures / gas rates




Inside the GID1 Volume 2



Checking of appliance gas safety devices / controls


Chimney standards and flue testing


Re-establishing gas supply / re-lighting appliances


Domestic gas meters


Landlords Gas Safety Record


LPG General requirements


Definitions, useful data, and references




Inside the NEW 5th Edition TTP1 Pocket Guide (Fully Updated to IGEM/UP/1B Edition 4)



Tightness Testing Procedures for Small Natural Gas Installations


Fluid and electronic pressure gauge usage


Permissible pressure drops for new and existing installations


Calculating installation volumes


Safety precautions prior to working on gas installations


Tightness testing procedures for new and existing gas installations


Purging Procedures for Small Natural Gas Installations


Calculating the necessary purge volume of an installation


Direct purging procedures including the differences when the installation volume is below and above 0.02 m3


The CORGI Direct Forms to Use (CP32)