Sauermann Sica 230 Kit 5NDS Combustion Flue Gas Analyser 27604

Part Code
SA51.0200
Man part no.
27604
Loading your price…
Checking stock…

Product Description

Manufacturers Part Number: 27604

**In Remote Warehouse Delivery 3-5 Days**

Si-CA 230

The Si-CA 230 offers everything heating engineers need to inspect and maintain residential and commercial boilers, with wireless connection to our smartphone app and automatic generation of servicing reports and certificates. The latest in combustion analysis technology with a compact, light and durable design. Gas Analyser for Emissions Monitoring of Boiler, Engine, & Other Combustion Applications. Accurate / Reliable / Robust / Innovative

Kit Descriptions

Si-CA 230-2 27522 Si-CA 230 Analyser includes two gas sensors (O2, CO),

Si-CA 230-3N 27597 Si-CA 230 Analyser includes three gas sensors (O2, CO, NO)

Si-CA 230-3NL 27598 Si-CA 230 Analyser includes three gas sensors (O2, CO, Low NO)

Si-CA 230-4ND 27599 Si-CA 230 Analyser includes four gas sensors (O2, CO, NO, NO2)

Si-CA 230-4NS 27600 Si-CA 230 Analyser includes four gas sensors (O2, CO, NO, SO2)

Si-CA 230-4NC 27601 Si-CA 230 Analyser includes four gas sensors (O2, CO, NO, CxHy)

Si-CA 230-4NLDL 27602 Si-CA 230 Analyser includes four gas sensors (O2, CO, Low NO, Low NO2)

Si-CA 230-4NLSL 27603 Si-CA 230 Analyser includes four gas sensors (O2, CO, Low NO, Low SO2)

Si-CA 230-5NDS 27604 Si-CA 230 Analyser includes five gas sensors (O2, CO, NO, NO2, SO2)

Si-CA 230-5NDC 27605 Si-CA 230 Analyser includes five gas sensors (O2, CO, NO, NO2, CxHy)

Si-CA 230-5NSC 27606 Si-CA 230 Analyser includes five gas sensors (O2, CO, NO, SO2, CxHy)

Si-CA 230-5NSH 27607 Si-CA 230 Analyser includes five gas sensors (O2, CO, NO, SO2, H2S)

Si-CA 230 230-5NLDLSL 27608 Analyser includes five gas sensors (O2, CO, Low NO, Low NO2, Low SO2)

Si-CA 230-6NDSC 27609 Si-CA 230 Analyser includes six gas sensors (O2, CO, NO, NO2, SO2, CxHy)

Si-CA 230-6NLDLSLH 27611 Si-CA 230 Analyser includes six gas sensors (O2, CO, Low NO, Low NO2, Low SO2, H2S)

Si-CA 230 kit content

Si-CA 230 analyser
O2 & CO gas sensors
CO Dilution Auto-Range to 50,000 ppm
Protective rubber holster
300 mm flue gas probe with 3 m dual hose (other probe lengths available)
Water trap with filter
AC power supply / charger
USB cable
Mobile app & PC software
Internal wireless communication module
Carrying case
Quick Start Guide
Calibration certificate
Features

Up to Six Gas Sensors. Can include O2, CO, NO, Low NO,NO2, Low NO2, SO2, Low SO2, H2S, and CxHy
CO Dilution auto-range with measurements to 50,000 ppm
Large Color Touch Screen
Total NOx & Low NOx Capable
iOS and Android Mobile Apps for Real-Time Display & Control
Field Replaceable Pre- Calibrated Sensors
Ergonomic, light weight, & durable design
Data management with automatic logging & report creation
Predictive maintenance with estimated sensor life & calibration reminders
One touch pump On/Off with purge
PC software with wireless and USB connectivity
Auto pump cut-off for high CO levels
Graphical data display
Customizable gas analysis screen
Sample conditioning unit for low NOx & high moisture applications
Stack gas velocity with Pitot tube
Draft & differential pressure measurements
Emissions values adjusted for reference O2
CO & CO2 Monitoring in Ambient Air
Hose extensions for tall & difficult to reach stacks
Wireless Printer
Protective rubber holster
Maintenance contracts and extended warranties available
Apps and software

Free apps for iOS & Android mobile devices
PC software with USB & wireless connectivity
Fast, easy wireless connection
Remote live view of combustion analysis data as list or graph
Remote control to change settings
Data saving, including automatic logging
Report creation in PDF, CSV (for Excel) and XML formats
Databases for customers, operators, & Equipment
General features

Dimensions 28 x 11.2 x 5.5 cm (11 x 4.3 x 2)

Weight 825 g (30 oz)

Display Color Touch Screen with Graphing; Size: 480 x 272 pixels

Keypad 1 On-Off key

Material ABS-PC

Protection IP42

Connection

- Wireless: class 2 range, range frequency from 2402 MHz to 2480 MHz

with a transmit power of 1 dBm.

Range up to 15 m (50 ft), depending on smartphone radio strength.

Minimum required versions: Android 8.0, iOS 12.4, BLE 4.0 Low Energy

- USB

Power supply

Rechargeable battery, USB power supply

Li-Ion 5100 mA/h 3.6 V battery / Power supply voltage of the mains unit: 100-240 Vac, 50-60 Hz

Mains unit: 5 Vdc/2A

Battery Battery life > 8 h; Charging time: Fully charge: < 6.5 h; 50%: < 2.5 h

Memory Internal memory up to 2000 tests

Environmental conditions of use

Temperature: from -5 to 45 C (23 to 113 F),

Hygrometry: in non-condensing conditions (< 85% RH)

Maximum altitude: 2000 m (6561)

Storage temperature From -20 to 50 C (-4 to 122 F)

Languages English, French, German, Spanish, Italian, Portuguese, Chinese

European Union Directives

2014/53/EU (RED); 2015/863 EU (RoHS 3)

Regulations

EN 50379-1 and EN 50379-2; UNI 7129; UNI 11137; UNI 10389; UNI 10845;

UL & cUL Certification; BS 7967:2015; BS EN 50543:2011; UNE 60670-10; ES.02173.ES;

TV SD Certification